Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to sign up for SAGE Journal Email Alerts today!

Sign In to gain access to subscriptions and/or personal tools.
The International Journal of Robotics Research
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
0278364909103785v1
28/9/1101    most recent
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Jayender, J.
Right arrow Articles by Nikumb, S.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Robot-assisted Active Catheter Insertion: Algorithms and Experiments

J. Jayender

The University of Western Ontario and Canadian Surgical Technologies & Advanced Robotics (CSTAR), London, Ontario, Canada, jayender{at}gmail.com

R.V. Patel

The University of Western Ontario and Canadian Surgical Technologies & Advanced Robotics (CSTAR), London, Ontario, Canada, rajni.patel{at}ihsc.on.ca

S. Nikumb

Integrated Manufacturing Technologies Institute (IMTI), National Research Council (NRC), London, Ontario, Canada, suwas.nikumb{at}nrc.gc.ca

Angioplasty is a frequently performed clinical procedure in which a catheter is inserted into a blood vessel under image guidance to open narrowed or blocked arteries and to allow normal blood flow to resume. This paper is concerned with the development of algorithms for a robot-assisted method for a more accurate, safer and more reliable approach for catheter insertion that can reduce the potential for injury to patients and radiation exposure or discomfort to clinicians. A force control algorithm is presented for a robot to control the force of insertion of a catheter and prevent the catheter from buckling or "bunching up" during insertion. In addition, the paper also describes a master—slave control strategy to precisely control the bending angle of the tip of an active catheter instrumented with Shape Memory Alloy (SMA) actuators. A novel model for SMAs and a robust H{infty} loop-shaping controller have been implemented to guarantee robust performance of the active catheter. The algorithms for catheter insertion developed in this paper may help to prevent damage to the epithelial cells of an artery and enable easier guidance of the catheter into appropriate branches. In addition, a robotics-based approach could make it possible for a clinician to remotely perform the insertion of the active catheter from a safe and comfortable environment, thereby reducing exposure to harmful X-ray radiation. Experimental results are presented to illustrate the performance of the algorithms.

Key Words: angioplasty • robot-assisted catheter insertion • force/position control • hybrid-impedance control • active catheter • shape-memory alloy actuators • master slave control

This version was published on September 1, 2009

The International Journal of Robotics Research, Vol. 28, No. 9, 1101-1117 (2009)
DOI: 10.1177/0278364909103785


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?